Charge points run for hours on a dedicated circuit. RCH’s guide lists the ordinary hazards: shock if a unit is badly fitted or misused, even when the enclosure is rated for outdoors; trips from trailing leads; and overloaded circuits, which is where fires start. The serious example they published was not theoretical.
What they found
They were called to a house, around 80 years old, because the household could smell burning near the mains. The consumer unit area showed burning around the service head. The meter tails were extremely hot. RCH called National Grid, the distribution network operator, rather than trying to “make it do”.
The service head was three-phase and also fed the neighbour through links, not fuses, on a single phase. The neighbour had recently had an EV charger installed and had noticed the lights flickering more than usual. In RCH’s account, the extra load was more than that shared supply arrangement could accept. A DNO assessment would have refused the charger as installed, because the service head was in another property. Putting in a diverted main was discussed as one possible remedy; on that occasion the repair was more complicated because of how the mains was arranged.
RCH is explicit that it did not install that charger. The lesson they drew is the one they apply to their own installs: a competent installer does a load check and submits the DNO application before the point is connected. If that step is skipped, the risk sits with the household.